Post
88 watts less
The rack drew 62.5 watts on average in October, against 150 with the old tower in March. Over a year that is 767 kWh, about 245 euros.
1 min
Watts, fans and the loft in summer, measured at the plug and at the disks.
Post
The rack drew 62.5 watts on average in October, against 150 with the old tower in March. Over a year that is 767 kWh, about 245 euros.
1 min
Post
The NAS fans follow the disk temperature now instead of running flat out from 40 °C. Ten seconds of the loft at 23:00 are below.
1 min
Changelog
A new role shuts the rack down in order when the UPS runs on battery: the nodes after five minutes, the NAS last. No breaking change.
A new role, nut, shuts the rack down in order when the UPS runs on battery: the three nodes after five minutes, the NAS last. Until now a long power cut would have ended with an empty battery and four disks stopping mid-write.Added
nut role: the NAS talks to the UPS over USB and serves its status, the nodes listen.make check, which runs the playbook with --check --diff against every host.Changed
common role sets the time zone to Europe/Berlin on every host.Fixed
nfs role restarted the NFS server on every run, even without a change.nut_mode: netserver
nut_ups_name: ups
nut_driver: usbhid-ups
nut_shutdown_after: 300
PostPaid members only
Hardware written off over five years, power and the domain: 457 euros a year. Every part with its price, and what I would buy differently.
1 min
Post
On 2026-08-12 the loft reached 36 °C at 16:00 and the NAS disks 47 °C. Three changes kept them at 41 °C on the next hot day.
1 min
Post
The loft is the one room nobody sleeps in, with a socket, a network cable from the router and space for a rack. It gets hot in summer.
1 min