Homelab

The loft at night, after the fan curves

The NAS fans follow the disk temperature now instead of running flat out from 40 °C. Ten seconds of the loft at 23:00 are below.

0:00
/0:06
The rack at night. Only the switch blinks.

Since the August heat the NAS fans ran at full speed from 40 °C, which in practice meant all day, and you could hear them in the bedroom below. They follow the disk temperature now: slow at 38 °C, full at 46 °C. On an October night the loft is below 15 °C and they barely turn.

fancontrol on the NAS

The drivetemp kernel module makes each disk’s temperature a hwmon sensor, so fancontrol can follow it like any other.

INTERVAL=10
FCTEMPS=hwmon2/pwm2=hwmon3/temp1_input
FCFANS=hwmon2/pwm2=hwmon2/fan2_input
MINTEMP=hwmon2/pwm2=38
MAXTEMP=hwmon2/pwm2=46
MINSTART=hwmon2/pwm2=80
MINSTOP=hwmon2/pwm2=40

The mini PCs

The three nodes have a fan curve in their firmware settings. Mine starts the fan at 50 °C. At idle they sit at 41 to 44 °C, so the fans stand still most of the night.

What it sounds like

audio-thumbnail
The loft at 23:00, recorded at the hatch
0:00
/10

What is left is the switch fan and the UPS. The phone app says 33 dB(A) at the hatch, down from 41. Trust the difference more than the numbers.