Incident
pve-2 keeps losing its network link
Three times in ten hours pve-2 dropped off the network for a few seconds and left the cluster. Power saving on its network card is the likeliest cause.
Monitoring
Minor
pve-2 lost its network link three times between Thursday evening and Friday morning, for 9 to 14 seconds each time. The cluster stayed quorate on the other two nodes, and the guests on pve-2 kept running, though nothing could reach them while the link was down. PCIe power saving on the network card is the likeliest cause, and it has been off since Friday 18:20. Then The other two nodes have the same card and have not dropped once, so the cause may sit in pve-2 itself. This stays at monitoring until pve-2 has gone a week without a drop. If it drops again, the cable and the switch port are next.Timeline
pcie_aspm=off. No drop since.What the log shows
$ journalctl -k --since "2026-11-12 21:40" --grep "Link is" --output short-iso
2026-11-12T21:47:03+01:00 pve-2 kernel: igc 0000:01:00.0 enp1s0: NIC Link is Down
2026-11-12T21:47:12+01:00 pve-2 kernel: igc 0000:01:00.0 enp1s0: NIC Link is Up 1000 Mbps Full Duplex, Flow Control: RX/TXThe change
--- a/etc/default/grub
+++ b/etc/default/grub
@@ -9 +9 @@
-GRUB_CMDLINE_LINUX_DEFAULT="quiet"
+GRUB_CMDLINE_LINUX_DEFAULT="quiet pcie_aspm=off"update-grub and a reboot, after its guests had moved to pve-1 and pve-3.Why it is not resolved yet